KEY TECHNICAL SPECIFICATION | ||||||
---|---|---|---|---|---|---|
ITEMS | MODEL | |||||
ARC 200 | ||||||
INPUT POWER VOLTAGE | AC240V (single phase) ±10% | |||||
Rated input power capacity(KVA) | 7 | |||||
Input voltage capacity(Hz) | 50/60 | |||||
no - load voltage (V) | 62 | |||||
output current ranges(A) | 20 - 200 | |||||
rated output voltage(V) | 27 | |||||
Duty Cycle(%) | 60 | |||||
Efficiency (%) | 85 | |||||
Power Factor | 0.93 | |||||
Weight(Kgs) | 8 | |||||
Overall Dimensions(mm) | 440×218×355 | |||||
Protection class | IP 23 | |||||
Driver adjustment range | 0.60 | |||||
Diameter of rod(mm) | 1.6 - 3.15 |
KEY TECHNICAL SPECIFICATION | ||||||
---|---|---|---|---|---|---|
ITEMS | MODEL | |||||
ARC 250 | ||||||
INPUT POWER VOLTAGE | AC400V (3 PHASE) ±15% | |||||
Rated input power capacity(KVA) | 9.4 | |||||
Input voltage capacity(Hz) | 50/60 | |||||
no - load voltage (V) | 62 | |||||
output current ranges(A) | 20 - 250 | |||||
rated output voltage(V) | 30 | |||||
Duty Cycle(%) | 60 | |||||
Efficiency (%) | 85 | |||||
Power Factor | 0.93 | |||||
Weight(Kgs) | 11 | |||||
Overall Dimensions(mm) | 945×218×355 | |||||
Protection class | IP 23 | |||||
Driver adjustment range | 0.60 | |||||
Diameter of rod(mm) | 1.6 - 4 |
KEY TECHNICAL SPECIFICATION | ||||||
---|---|---|---|---|---|---|
ITEMS | MODEL | |||||
ARC 300 | ||||||
INPUT POWER VOLTAGE | AC440V (3 PHASE) ±15% | |||||
Rated input power capacity(KVA) | 12 | |||||
Input voltage capacity(Hz) | 50/60 | |||||
no - load voltage (V) | 69 | |||||
output current ranges(A) | 20 - 300 | |||||
rated output voltage(V) | 33 | |||||
Duty Cycle(%) | 60 | |||||
Efficiency (%) | 85 | |||||
Power Factor | 0.93 | |||||
Weight(Kgs) | 18 | |||||
Overall Dimensions(mm) | 580×320×495 | |||||
Protection class | IP 23 | |||||
Driver adjustment range | 0.100 | |||||
Diameter of rod(mm) | 1.6 - 4 |
KEY TECHNICAL SPECIFICATION | ||||||
---|---|---|---|---|---|---|
ITEMS | MODEL | |||||
ARC 350 | ||||||
INPUT POWER VOLTAGE | AC440V (3 PHASE) ±15% | |||||
Rated input power capacity(KVA) | 12.8 | |||||
Input voltage capacity(Hz) | 50/60 | |||||
no - load voltage (V) | 69 | |||||
output current ranges(A) | 20 - 350 | |||||
rated output voltage(V) | 33 | |||||
Duty Cycle(%) | 60 | |||||
Efficiency (%) | 85 | |||||
Power Factor | 0.93 | |||||
Weight(Kgs) | 25 | |||||
Overall Dimensions(mm) | 580×320×495 | |||||
Protection class | IP 23 | |||||
Driver adjustment range | 0.100 | |||||
Diameter of rod(mm) | 1.6 - 5 |
KEY TECHNICAL SPECIFICATION | ||||||
---|---|---|---|---|---|---|
ITEMS | MODEL | |||||
ARC 400 | ||||||
INPUT POWER VOLTAGE | AC440V (3 PHASE) ±15% | |||||
Rated input power capacity(KVA) | 18 | |||||
Input voltage capacity(Hz) | 50/60 | |||||
no - load voltage (V) | 69 | |||||
output current ranges(A) | 20 - 400 | |||||
rated output voltage(V) | 36 | |||||
Duty Cycle(%) | 60 | |||||
Efficiency (%) | 85 | |||||
Power Factor | 0.93 | |||||
Weight(Kgs) | 28.5 | |||||
Overall Dimensions(mm) | 580×320×495 | |||||
Protection class | IP 23 | |||||
Driver adjustment range | 0.130 | |||||
Diameter of rod(mm) | 1.6 - 5 |
KEY TECHNICAL SPECIFICATION | ||||||
---|---|---|---|---|---|---|
ITEMS | MODEL | |||||
ARC 630 | ||||||
INPUT POWER VOLTAGE | AC440V (3 Phase) ±15% | |||||
Rated input power capacity(KVA) | 35 | |||||
Input voltage capacity(Hz) | 50/60 | |||||
no - load voltage (V) | 72 | |||||
output current ranges(A) | 40 - 630 | |||||
rated output voltage(V) | 44 | |||||
Duty Cycle(%) | 60 | |||||
Efficiency (%) | 85 | |||||
Power Factor | 0.95 | |||||
Weight(Kgs) | 55 | |||||
Overall Dimensions(mm) | 670×395×633 | |||||
Protection class | IP 23 | |||||
Driver adjustment range | 0.150 | |||||
Diameter of rod(mm) | 2.4 - 8 gouging |